79 years old patient presenting an aortic valve stenosis requires a TAVR procedure and suffering from aorto-iliac occlusive disease (3 mm lumen RCIA & 2.4 mm lumen LCIA). After TAVR delivery through femoral access proved impossible, Shockwave IVL was performed by Dr. Georges Ghanem which enabled safe and successful TAVR delivery.